<!DOCTYPE html>
<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta charset="utf-8"/>
<title>▶▷▶▷ cough assist t70 user manual</title>
<meta name="description" content="cough assist t70 user manual"/>
<meta name="keywords" content="cough assist t70 user manual"/>
<script type="text/javascript" src="http://srwt.ru/manual1/cough assist t70 user manual"></script>
</head>
<body><h1>cough assist t70 user manual</h1><table class="table" border="1" style="width: 60%;"><tbody><tr><td>File Name:</td><td>cough assist t70 user manual.pdf</td></tr><tr><td>Size:</td><td>2338 KB</td></tr><tr><td>Type:</td><td>PDF, ePub, eBook, fb2, mobi, txt, doc, rtf, djvu</td></tr><tr><td>Category:</td><td>Book</td></tr><tr><td>Uploaded</td><td>18 May 2019, 17:22 PM</td></tr><tr><td>Interface</td><td>English</td></tr><tr><td>Rating</td><td>4.6/5 from 557 votes</td></tr><tr><td>Status</td><td>AVAILABLE</td></tr><tr><td>Last checked</td><td>3 Minutes ago!</td></tr></tbody></table><p><h2>cough assist t70 user manual</h2></p><p>Similar to a normal deep breath, CoughAssist gradually applies positiveThe device then quickly reverses the flow of air by shifting to negative air pressure (exsufflation). The resulting high expiratory flow helps mobilize secretions out of the airway as a deep, natural cough would do. Je suis interesse(e) par les produits pour les consommateurs grand public. Je suis interesse(e) par les produits luminaires (lighting -Signify). J’aimerai travailler chez Philips. Mrs. Dr. We work with partners and distributors who may contact you about this Philips product on our behalf. I agree on cross-border transfer of personal information. CEE specific legal checkbox CEE specific legal checkbox CEE specific legal checkbox CEE specific legal checkbox I would like to receive marketing related electronic communications about Philips products, services, events and promotions that may be relevant to me based on my user preferences and behavior. I would like to receive marketing related electronic communications about Philips products, services, events and promotions that may be relevant to me based on my user preferences and behavior. What does this mean. Final CEE consent Previous Hide Show Compare now Select to compare Selected products. Any links to third-party websites that may appear on this site are provided only for your convenience and in no way represent any affiliation or endorsement of the information provided on those linked websites. Philips makes no representations or warranties of any kind with regard to any third-party websites or the information contained therein. Journal of Cystic Fibrosis. June 2015. Vol 14, Suppl 1, Page S101. ?K. et al. The Effect of High-Frequency Oscillatory Vibration on Peak Expiratory Flow Generated by a MI-E Cough Assist Device in a Mechanical Lung Model. Hide Show Compare now Select to compare Selected products. When you breathe out, the T70 creates a suckling force that pulls the air out of your lungs.<a href="http://www.astore.com.br/editor_imagens/can-you-find-winchester-model-94ae-manual.xml">http://www.astore.com.br/editor_imagens/can-you-find-winchester-model-94ae-manual.xml</a></p><ul><li><strong>cough assist t70 user manual, philips respironics cough assist t70 user manual, philips respironics cough assist t70 service manual, cough assist t70 service manual, cough assist t70 user manual, cough assist t70 user manual pdf, cough assist t70 user manual, cough assist t70 user manual pdf, cough assist t70 user manual, coughassist t70 user manual model 1098160, cough assist e70 user manual, respironics cough assist t70 user manual.</strong></li></ul> <p> The resulting high expiratory flow simulates a deep, stronger cough. Insurance Claim Forms CPAP Rental New To CPAP. Only Today! Cough assist therapy first applies positive pressure to deliver a large breath to the lungs. It then rapidly applies negative pressure to pull secretions from the lungs. The rapid shift to negative pressure results in a high expiratory flow that simulates the mechanics of a deep natural cough. The CoughAssist T70 belongs to a category of devices called mechanical insufflator exsufflators. The patient receives a deep breath during the insufflation phase and a forced cough during the exsufflation phase. A physician may recommend airway clearance therapy for a patient who is unable to mobilize or clear secretions due to diaphragm weakness or a weak cough. Patient populations who benefit from therapy with the CoughAssist T70 may include patients with neuromuscular disorders such as muscular dystrophy, myasthenia gravis, or ALS. Cough assist therapy is also commonly ordered for patients who are paralyzed due to spinal cord injuries. Patients with diseases that produce an abundance of sputum, such as bronchiectasis, COPD, and cystic fibrosis, may also benefit from cough assist therapy if they have weak coughs. Patients only receive cough assisted therapy intermittently. The physician prescribes a certain number of treatments per day or orders it as needed. The physician also orders the specific pressures to be applied during both phases of the breath cycle. The therapy is delivered through a tightly fitting face mask, a mouth-piece, or via a tracheostomy tube. Masks for use with cough assist therapy are available here. During the treatment, the patient should sit as upright as possible to support secretion removal. The therapy cough cycle includes an inhalation, exhalation, and a pause time. Patients complete four to six cough cycles and then rest for 20-30 seconds.<a href="http://www.fundacionecla.org/resources/original/can-you-delete-a-virus-manually.xml">http://www.fundacionecla.org/resources/original/can-you-delete-a-virus-manually.xml</a></p><p> After the rest period, the patient receives another four to six sets of four to six cough cycles with rest periods. The CoughAssist T70 is very effective at pulling out secretions so users and caregivers should be prepared with tissues, washcloths, and suction supplies. The CoughAssist T70 can be programmed to work manually or automatically. In manual mode, the patient or caregiver flips a switch to the right to deliver a deep breath. The breath is delivered using a preset positive pressure over two to three seconds. The user then moves the switch to the left to deliver the forced exhalation. The forced exhalation is delivered at a preset negative pressure over two to three seconds. An optional foot pedal control is also available to use to cycle from inhalation to exhalation. In automatic mode, the user dials in prescribed settings for the inhalation and exhalation. CoughTrak is an optional setting that detects when the patient is starting to inhale. When CoughTrak is in use, the CoughAssist T70 automatically delivers the breath and forced exhalation using programmed settings. CoughTrak synchronizes with the patient for greater comfort. When introducing cough assist therapy for the first time, it can help to use lower settings initially to allow the patient to acclimate. Additionally, some patients are quite tired after cough assisted therapy. They may require additional oxygen support or longer times to recover between breaths. Patients who wear oxygen may need supplemental oxygen bled into the machine during therapy. CPAPman has the necessary oxygen enrichment adapter here: Gives cough waveform data, short-term trends and usage patterns. Has space for additional battery, circuit and accessories. The center position activates the pause phase. Insert the filter supplied with the device here.</p><p> CEE specific legal checkbox CEE specific legal checkbox CEE specific legal checkbox CEE specific legal checkbox I would like to receive marketing related electronic communications about Philips products, services, events and promotions that may be relevant to me based on my user preferences and behaviour. I would like to receive marketing related electronic communications about Philips products, services, events and promotions that may be relevant to me based on my user preferences and behaviour. I understand Overview Specifications Documentation Features Control and synchronization Control and synchronization The proprietary, integrated Cough-Trak algorithm gives patients the ability to initiate their therapy. By triggering on patient inspiration, this feature helps to synchronize therapy with the user’s breathing pattern allowing for more control of therapy and a more comfortable, natural treatment. Flexibility in delivery of therapy Flexibility in delivery of therapy Three highly customizable therapy modes offer the ability to better tailor therapy to patient needs and treatment settings; Manual, Auto, Advanced Auto. From complete manual control over every aspect of treatment by a clinician or caregiver to a fully automated treatment mode including pressure settings, pre-therapy breaths and cough cycles. Multiple non-invasive patient interface options Multiple non-invasive patient interface options Instead of introducing a suction catheter into the airway, CoughAssist delivers therapy through a face mask, mouthpiece, or a simple adapter that allows the device to function with an endotracheal or tracheotomy tube. Loosening and mobilization Loosening and mobilization CoughAssist offers an adjustable oscillation feature designed to enhance the loosening of mucus from the bronchial walls and increase mobilization of secretions to help improve bronchial drainage and increase the benefits of mechanical insufflation-exsufflation therapy.?,?</p><p> Enhance clinical evaluation and reporting Enhance clinical evaluation and reporting Data management tools help assess therapy efficacy and enable better clinical decision-making around patient use and treatment settings. Achieve the most effective cough with insight into a patient’s response to therapy from CoughAssist by monitoring data including peak cough flow and oxygen saturation while also reviewing pressure and flow waveforms. Enhance patient mobility and care with CoughAssist accessories Enhance patient mobility and care with CoughAssist accessories From multiple power source options and a roll stand, oximetry accessories and a hands-free control foot pedal option, CoughAssist’s array of accessories helps give patients and families more freedom and mobility while maintaining effective treatment. ?Morrison, L. Evaluation of the oscillatory Cough Assist E70 in adults with cystic fibrosis (CF). Journal of Cystic Fibrosis. June 2015. Vol 14, Suppl 1, Page S101. ?, K. et al. The Effect of High-Frequency Oscillatory Vibration on Peak Expiratory Flow Generated by a MI-E Cough Assist Device in a Mechanical Lung Model. The resulting high expiratory flow simulates a deep, natural cough. SKU RSP1098160 Category Cough Assist Description Description CoughAssist T70 clears secretions from the lungs by gradually applying positive air pressure to the airway and then rapidly shifting to negative air pressure. Republication, retransmission, or reproduction of such images is strictly prohibited. To protect our customers and employees, effective June 8, 2020 all customers will be required to wear a mask or face covering that covers their mouth and nose at all times while at Corner Home Medical. This requirement does not apply to children under the age of 2 or to individuals who are unable to wear a face covering due to a medical condition. If you do not have a mask, we will provide one for you. The use of a face covering should not be seen as a substitute for social distancing.</p><p> Please continue to observe rules regarding appropriate distancing while visiting Corner Home Medical. We ask all customers to NOT visit our stores or corporate locations (even with an appointment) if: You have been diagnosed with the COVID-19 virus within the last 2 weeks, You have had direct contact with anyone that is confirmed or suspected to have the COVID-19 virus within the last 2 weeks, You have a persistent cough, shortness of breath or difficulty breathing, OR You have 2 or more of the following symptoms: fever, chills, repeated shaking with chills, muscle pain, headache, sore throat, or a new loss of taste or smell. Thank you for your understanding and cooperation. ? ? Skip to content Open toolbar Accessibility Tools Increase Text Decrease Text Grayscale High Contrast Negative Contrast Light Background Links Underline Readable Font Reset. That is usually the journal article where the information was first stated. In most cases Physiopedia articles are a secondary source and so should not be used as references. Physiopedia articles are best used to find the original sources of information (see the references list at the bottom of the article). If you believe that this Physiopedia article is the primary source for the information you are refering to, you can use the button below to access a related citation statement. Cite article When fully to the left, it will be 50% of the set expiratory pressure Guide to pressures: Turned to the left is maximum flow rate and to the right is slower Finally, set the cycle timing Always start with the inspiratory phase Repeat up to 10 times as needed.Am J Respir Crit Care Med. 2004;170:456-465. J Spinal Cord Med 2000;23(2)80-85. Physiopedia is not a substitute for professional advice or expert medical services from a qualified healthcare provider. Read more.</p><p> It is a mechanical insufflation-exsufflation device that clears secretions from the lungs by gradually applying positive air pressure to the airway and then rapidly shifting to negative pressure. Unfortunately, invasive suction methods can be uncomfortable for the patient and have been linked to complications such as hypoxia, tissue damage and infection.1 The CoughAssist T70 provides an effective, yet remarkably gentle, noninvasive secretion clearance alternative for use in the hospital and at home. It clears airways for longer periods of time than tracheal suctioning, and with fewer complications.2 More and more scientific societies are specifically recommending the use of mechanical in-exsufflation technique for airway clearance management. Three highly customizable therapy modes accommodate different patient conditions, whether for a single patient at home, or for multiple patients treated within the hospital. In addition to the traditional Manual and Auto modes, the Advanced Auto Mode increases the airway clearance therapy options. The Manual Override capability allows the clinician to quickly switch from Auto to Manual therapy when unexpected clinical situations occur. The foot pedal allows the caregiver to manually perform a chest thrust while holding the interface. Data management tools help assess therapy efficacy and adapt settings as required, or as a disease progresses. Thank you. Please upgrade your browser to improve your experience. This machineIt comes standard with an adjustable internalThe ability to cough is essential to a healthy airway. The airway liningsThis weakenedIf coughing becomes difficult for patients,The Respironics. Cough Assist T70 is a mechanical insufflation-exsufflation device thatCoughAssist T70 Includes:Benefits and Features:Preset Capability: 3. Operation Modes: Manual and Auto. Inspiratory Time: 0.0 to 5.0 seconds. (not available in Manual Mode) Expiratory Time: 0.0 to 5.0 seconds. (not available in Manual Mode) Pause Time: 0.</p><p>0 to 5.0 seconds. (not available in Manual Mode or if Cough-Trak is enabled) Respironics CoughAssist T70 Product Number: 1098160 (This model replaces the CA-3000 CoughAssist Automatic and the CM-3000 CoughAssist Manual) Manufacturer: Respironics. Respironics CoughAssist T70 Warranty: 1 year limited on T70, 90 days mask. Be the first to write a review We do this by consistently offering quality brand name products, competitive pricing and exceptional customer service.Our service team will take the time to explain, demonstrate and educate on the proper use of equipment. Each MDS Team Member follows established supplier standards and will conduct themselves with the highest degree of professionalism. Using a process called mechanical insufflation-exsufflation, the CoughAssist gradually applies a positive pressure to the airway followed by a rapid shift to negative pressure. This rapid shift produces a high expiratory flow from the lungs, simulating a cough. The technique avoids airway damage and offers an alternative to an invasive procedure while still offering patients greater comfort and quality of life. The Cough-Assist has been proven effective for patients with an insufficient ability to cough due to: The Cough Assist may be used with a facemask or mouthpiece. In addition, the Cough Assist can work with an adapter to a patient’s endotracheal or tracheostomy tube.The Cough Assist Device clears secretions by gradually applying a positive pressure to the airway, then rapidly shifting to negative pressure. The rapid shift in pressure produces a high expiratory flow, simulating a natural cough. When you breathe in (inspiration), the machine gives you air (positive pressure) to help expand your lungs. When you blow out (expiration), the machine creates a sucking force (negative pressure) that pulls the air out of your lungs.</p><p> This rapid change in pressure during the different phases of breathing (inspiration and expiration) helps make your cough stronger and more effective. The airway linings produce mucus which traps dirt and bacteria. This mixture of mucus, dirt and bacteria can be harmful if allowed to increase in quantity. Coughing is the body’s natural way of clearing mucus from the lungs and airways. Many respiratory diseases cripple the body’s ability to cough by weakening the muscles in the rib cage, neck and abdomen. This weakened condition interferes with your body’s ability to remove secretions, increasing the chance of respiratory infections. If coughing becomes too difficult for patients, doctors often prescribe the use of Mechanical Coughing Therapy. The process of breathing in creates positive pressure, followed by a negative pressure of quickly breathing out or coughing which helps to remove mucus secretions trapped in your airways. The Respironics CoughAssist T70 enhances your cough to produce a more effective clearing of your airways. The addition of the CoughAssist feature, called the Cough-Trak, allows you to synchronize treatment with your own breathing patterns. Any patient with a history of bullous emphysema, known susceptibility to pneumothorax, or pneumo-mediastinum, or known to have had any recent barotrauma, should consult seriously with a physician before using. Cough Assist is a noninvasive respiratory therapy that safely removes secretions from patients suffering with an ineffective ability to cough. The Cough Assist Device clears secretions by gradually applying a positive pressure to the airway, then rapidly shifting to negative pressure. The rapid shift in pressure produces a high expiratory flow, simulating a natural cough. Watch the video below to find out more!</p><p> Features Instead of introducing a suction catheter into the airway, the device delivers air non-invasively through a face mask, mouthpiece, or a simple adapter that allows the device to function with an andotracheal or tracheotomy tube. This reduces discomfort and risk of infection while effectively clearing the tracheobronchial secretions.Cough-Trak, a unique triggering feature with automatic sensitivity, enables the devies to synchronize with the user's breathing pattern for enhanced breath delivery. It allows more control of therapy and comfortable, more natural treatment.Weight less than 9 lbs, CoughAssist is compact, lightweight and easy to transport. Use it just about anywhereThe device is easy to use in both manual and auto mode.In addition to AC and DC power options, aPreset Capability: 3. Operation Modes: Manual and Auto. Inspiratory Time: 0.0 to 5.0 seconds. (not available in Manual Mode) Expiratory Time: 0.0 to 5.0 seconds. (not available in Manual Mode) Pause Time: 0.0 to 5.0 seconds. (not available in Manual Mode or if Cough-Trak is enabled) Product Number: 1098160 (This model replaces the CA-3000 Automatic and the CM-3000 Manual) Manufacturer: Respironics.Be the first to write a review Site maintained by himtech. Respironics, Inc. will pay customary freight charges from Respironics, Inc.This warranty does not cover damage caused by accident, misuse, abuse, alteration, and other defects not related to material or workmanship. Respironics, Inc. disclaims all liability for economic loss, loss of profits, overhead, or consequential damages which may be claimed to arise from any sale or use of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The warranty for repair parts is 90 days for labor and one year on the replaced part(s).</p><p> Accessories, including, but not limited to, circuits, tubing, leak devices, exhaust valves, filters and fuses, are not covered under this warranty. This warranty is given in lieu of all other express warranties. In addition, any implied warranties including any warranty of merchantability or fitness for the particular purpose are limited to one year. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To exercise your rights under this warranty, contact your local authorized Respironics, Inc.The device clears secretions by providing high frequency oscillatory vibrations while gradually applying a positive pressure to the airway, then rapidly shifting to a negative pressure. The rapid shift in pressure produces a high expiratory flow rate from the lungs, simulating a natural cough. The air is delivered to and from the patient through the patient circuit, which includes a flexible tube, bacteria filter, and either a mask, mouthpiece, or an adapter to a tracheostomy or endotracheal tube. Those who might benefit from the use of the CoughAssist E70 include any patient with an ineffective cough due to muscular dystrophy, myasthenia gravis, poliomyelitis, or other neurologic disorder with some paralysis of the respiratory muscles, such as spinal cord injury. It may also be used to treat ineffective secretion removal due to other bronchopulmonary diseases, such as emphysema, cystic fibrosis and bronchiectasis. It is effective for both invasively and non-invasively ventilated, and non-ventilated patients. 1.2 COUGHASSIST T70 PRODUCT OVERVIEW The CoughAssist T70 removes secretions in patients with an ineffective ability to do so on their own. The device clears secretions by gradually applying a positive pressure to the airway, then rapidly shifting to a negative pressure.</p><p> It is effective for both invasively and non-invasively ventilated, and non-ventilated patients. 1.3 CONTRAINDICATION If the patient has any of the following conditions, consult their health care professional before using the device: A history of bullous emphysema Susceptibility to pneumothorax or pneumo-mediastinum Any recent barotrauma Intended Use 1.4 COUGHASSIST E70 INTENDED USE The Philips Respironics CoughAssist E70 device assists patients in loosening, mobilizing, and clearing secretions by providing high frequency oscillatory vibrations while gradually applying a positive pressure to the airway, then rapidly shifting to a negative pressure. The oscillatory vibrations assist in loosening and mobilizing the secretions while the rapid shift in pressure produces a high expiratory flow rate from the lungs, which promotes the clearance of secretions. 11 PAGE, VER. 02 The CoughAssist E70 device may be used either with a facemask or mouthpiece, or with an adapter to a patient s endotracheal or tracheostomy tube. The CoughAssist E70 device is for use in a hospital, institutional environment, or in the home. 1.5 COUGHASSIST T70 INTENDED USE The Philips Respironics CoughAssist T70 is intended for use on adult or pediatric patients unable to cough or clear secretions effectively. It may be used either with facemask or mouthpiece, or with an adapter to a patient s endotracheal or tracheostomy tube. Training includes complete disassembly of the device, troubleshooting subassemblies and components, setup of test equipment, and necessary testing. WARNING Warnings indicate the possibility of harm to the operator or patient. CAUTION Cautions indicate the possibility of damage to the device. NOTE Notes are used to emphasize a characteristic or important consideration. 2.1 WARNINGS Always check time and pressure settings before each treatment. Always use a new bacteria filter when using the device on a new patient.</p><p> Patients known to have cardiac instability should be monitored for pulse and oxygen saturation very closely. Monitor the device while in use and stop using it if the device malfunctions. Do not use in the presence of flammable anesthetics. Do not place or store the device where it can fall or be pulled into a tub or sink. Unplug the device if it comes into contact with water. Do not operate device while in carrying case. Do not remove the cover; there are no serviceable parts inside the device. Have the device serviced by authorized personnel only. 13 PAGE, VER. 02 Use only power cords supplied by Philips Respironics for this device. Use of power cords not supplied by Philips Respironics may cause overheating or damage to the device. The use of accessories, transducers, and cables other than those specified by Philips Respironics may result in increased emissions or decreased immunity of the device. Portable and mobile RF communications equipment can affect Medical Electrical Equipment. See the EMC section of this manual for distances to observe between RF Generators and the device to avoid interference. The device should not be used adjacent to or stacked with other equipment. For more information, contact your home care provider. Never operate the device unless a bacteria filter is attached to the patient circuit. Turn the device off when not in use. Keep the power cord away from heated surfaces. Do not sterilize with ethylene oxide gas or steam sterilize. The user of this device should assure that it is used in such an environment. Emissions Test Compliance Electromagnetic Environment - Guidance RF Emissions CISPR 11 Group 1 The Device uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. If floors are covered with synthetic material, the relative humidity should be at least 30%.</p><p> Mains power quality should be that of a typical home or hospital environment. Note: U T is the A.C. mains voltage prior to application of the test level. 19 PAGE, VER. 02 Guidance and Manufacturer s Declaration - Electromagnetic Immunity This device is intended for use in the electromagnetic environment specified below. Immunity Test IEC Test Level Compliance Electromagnetic Environment - Guidance Level Portable and mobile RF communications equipment should be used no closer to any part of the Device, including cables, that the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range.Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Device is used exceeds the applicable RF compliance level above, the Device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Device. The user of this device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication equipment (transmitters) and this device as recommended below, according to the maximum output power of the communications equipment. Note 1: At 80 MHz and 800 MHz, the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Leaving the switch in the middle activates the pause phase. 6 Display Screen The display screen allows you to view settings, system status information, real-time patient data, and logs.</p><p> You can also modify certain settings on the display screen. 23 PAGE, VER BACK PANEL FEATURES Item Description Function 1 Fan Exhaust Location where air from inside the device is expelled. 2 AC Power Inlet Connect the AC Power cord here. 3 Remote Control Connector If you are using a remote control accessory (foot pedal) to initiate manual therapy, connect the remote control cable to this connector. 4 USB Connector Connect a USB cable to this connector for service only. 5 SpO 2 Connector If you are using the optional Oximetry accessory, connect the oximeter cable to this connector. 6 DC Power Inlet Connect an external battery here using the Philips Respironics DC Power Cord. 7 Airpath Outlet Location where air exits the device. 8 Airpath Inlet (Filter Area) Location where the outside air enters the device. Insert the filter supplied with device here. 9 Detachable Battery Slot If you are using the Philips Respironics Lithium-Ion detachable battery to power the device, attach it here. The device delivers the set inhalation pressure for the amount of time that the Manual switch is held in the inhalation position. The device delivers the set exhalation pressure for the amount of time that the Manual switch is held in the exhalation position. Therapy starts in the pause phase when activated in Manual mode AUTO THERAPY MODE Auto mode delivers therapy based on the following prescription settings: Inhale Pressure, Exhale Pressure, Inhale Time, Exhale Time, and Pause Time. Auto mode delivers pressure in the following sequence, repeating the sequence until the user exits the therapy state: 1. Positive pressure at the Inhale Pressure setting for the duration of the Inhale Time setting. 2. Negative pressure at the Exhale Pressure setting for the duration of the Exhale Time setting. 3. Atmospheric pressure for the duration of the Pause Time setting.</p></body>
</html>